Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Thromb Thrombolysis ; 53(1): 103-112, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34272635

RESUMO

Coagulopathy is a key feature of COVID-19 and D-dimer has been reported as a predictor of severity. However, because D-dimer test results vary considerably among assays, resolving harmonization issues is fundamental to translate findings into clinical practice. In this retrospective multicenter study (BIOCOVID study), we aimed to analyze the value of harmonized D-dimer levels upon admission for the prediction of in-hospital mortality in COVID-19 patients. All-cause in-hospital mortality was defined as endpoint. For harmonization of D-dimer levels, we designed a model based on the transformation of method-specific regression lines to a reference regression line. The ability of D-dimer for prediction of death was explored by receiver operating characteristic curves analysis and the association with the endpoint by Cox regression analysis. Study population included 2663 patients. In-hospital mortality rate was 14.3%. Harmonized D-dimer upon admission yielded an area under the curve of 0.66, with an optimal cut-off value of 0.945 mg/L FEU. Patients with harmonized D-dimer ≥ 0.945 mg/L FEU had a higher mortality rate (22.4% vs. 9.2%; p < 0.001). D-dimer was an independent predictor of in-hospital mortality, with an adjusted hazard ratio of 1.709. This is the first study in which a harmonization approach was performed to assure comparability of D-dimer levels measured by different assays. Elevated D-dimer levels upon admission were associated with a greater risk of in-hospital mortality among COVID-19 patients, but had limited performance as prognostic test.


Assuntos
COVID-19 , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Biomarcadores/sangue , COVID-19/diagnóstico , Humanos , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Espanha/epidemiologia
2.
Eur J Clin Invest ; 51(6): e13532, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33660278

RESUMO

BACKGROUND: Myocardial injury is a common finding in COVID-19 strongly associated with severity. We analysed the prevalence and prognostic utility of myocardial injury, characterized by elevated cardiac troponin, in a large population of COVID-19 patients, and further evaluated separately the role of troponin T and I. METHODS: This is a multicentre, retrospective observational study enrolling patients with laboratory-confirmed COVID-19 who were hospitalized in 32 Spanish hospitals. Elevated troponin levels were defined as values above the sex-specific 99th percentile upper reference limit, as recommended by international guidelines. Thirty-day mortality was defined as endpoint. RESULTS: A total of 1280 COVID-19 patients were included in this study, of whom 187 (14.6%) died during the hospitalization. Using a nonspecific sex cut-off, elevated troponin levels were found in 344 patients (26.9%), increasing to 384 (30.0%) when a sex-specific cut-off was used. This prevalence was significantly higher (42.9% vs 21.9%; P < .001) in patients in whom troponin T was measured in comparison with troponin I. Sex-specific elevated troponin levels were significantly associated with 30-day mortality, with adjusted odds ratios (ORs) of 3.00 for total population, 3.20 for cardiac troponin T and 3.69 for cardiac troponin I. CONCLUSION: In this multicentre study, myocardial injury was a common finding in COVID-19 patients. Its prevalence increased when a sex-specific cut-off and cardiac troponin T were used. Elevated troponin was an independent predictor of 30-day mortality, irrespective of cardiac troponin assay and cut-offs to detect myocardial injury. Hence, the early measurement of cardiac troponin may be useful for risk stratification in COVID-19.


Assuntos
COVID-19/sangue , Cardiomiopatias/sangue , Mortalidade , Troponina I/sangue , Troponina T/sangue , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Prognóstico , Estudos Retrospectivos , SARS-CoV-2 , Índice de Gravidade de Doença
3.
Scand J Clin Lab Invest ; 81(3): 187-193, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33591234

RESUMO

Identification of predictors for severe disease progression is key for risk stratification in COVID-19 patients. We aimed to describe the main characteristics and identify the early predictors for severe outcomes among hospitalized patients with COVID-19 in Spain. This was an observational, retrospective cohort study (BIOCOVID-Spain study) including COVID-19 patients admitted to 32 Spanish hospitals. Demographics, comorbidities and laboratory tests were collected. Outcome was in-hospital mortality. For analysis, laboratory tests values were previously adjusted to assure the comparability of results among participants. Cox regression was performed to identify predictors. Study population included 2873 hospitalized COVID-19 patients. Nine variables were independent predictors for in-hospital mortality, including creatinine (Hazard ratio [HR]:1.327; 95% Confidence Interval [CI]: 1.040-1.695, p = .023), troponin (HR: 2.150; 95% CI: 1.155-4.001; p = .016), platelet count (HR: 0.994; 95% CI: 0.989-0.998; p = .004) and C-reactive protein (HR: 1.037; 95% CI: 1.006-1.068; p = .019). This is the first multicenter study in which an effort was carried out to adjust the results of laboratory tests measured with different methodologies to guarantee their comparability. We reported a comprehensive information about characteristics in a large cohort of hospitalized COVID-19 patients, focusing on the analytical features. Our findings may help to identify patients early at a higher risk for an adverse outcome.


Assuntos
COVID-19/diagnóstico , Serviço Hospitalar de Emergência , SARS-CoV-2 , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/mortalidade , Feminino , Mortalidade Hospitalar , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espanha/epidemiologia , Adulto Jovem
4.
Rev. lab. clín ; 11(4): 209-216, oct.-dic. 2018. tab
Artigo em Espanhol | IBECS | ID: ibc-176919

RESUMO

Los laboratorios clínicos son frecuentemente requeridos para la identificación de líquidos corporales de los que se desconoce su origen. La información bibliográfica con respecto a la identificación de líquidos biológicos de procedencia incierta es escasa. El objetivo de este documento es actualizar los conocimientos sobre aquellos constituyentes útiles como marcadores para la identificación y diferenciación de estos líquidos. Se abordan aspectos como la identificación de una punción lumbar traumática o de líquido cefalorraquídeo en fístulas, la identificación de un derrame quiloso o pseudoquiloso, de secreción biliar, pancreática, gastroesofágica o de orina en las cavidades serosas así como del líquido amniótico


Clinical laboratories are regularly requested to analyze unusual body fluids of unknown origin. There is little in the literature about the identification of body fluids of uncertain origin. The purpose of this document is to perform an updated review on those constituents that may be useful as markers for identifying and diferentiating these unusual fluids. A review is presented on aspects such as the identification of a traumatic lumbar puncture or a cerebrospinal fluid leakage, the identification of a chylous or pseudochylous effusion, leakage of bile, pancreatic fluid, gastroesophageal fluid, or urine, in the serous cavities, as well as the amniotic fluid


Assuntos
Humanos , Secreções Corporais/química , Testes de Química Clínica/métodos , Técnicas de Laboratório Clínico/métodos , Líquido Cefalorraquidiano/química , Líquido Ascítico/química , Bile/química , Líquido Amniótico/química , Relatório de Pesquisa
6.
J Hepatol ; 67(4): 669-679, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28527664

RESUMO

BACKGROUND & AIMS: Studying hepatitis delta virus (HDV) and developing new treatments is hampered by the limited availability of small animal models. Herein, a description of a robust mouse model of HDV infection that mimics several important characteristics of the human disease is presented. METHODS: HDV and hepatitis B virus (HBV) replication competent genomes were delivered to the mouse liver using adeno-associated viruses (AAV; AAV-HDV and AAV-HBV). Viral load, antigen expression and genomes were quantified at different time points after AAV injection. Furthermore, liver pathology, genome editing, and the activation of the innate immune response were evaluated. RESULTS: AAV-HDV infection initiated HDV replication in mouse hepatocytes. Genome editing was confirmed by the presence of small and large HDV antigens and sequencing. Viral replication was detected for 45days, even after the AAV-HDV vector had almost disappeared. In the presence of HBV, HDV infectious particles were detected in serum. Furthermore, as observed in patients, co-infection was associated with the reduction of HBV antigen expression and the onset of liver damage that included the alteration of genes involved in the development of liver pathologies. HDV replication induced a sustained type I interferon response, which was significantly reduced in immunodeficient mice and almost absent in mitochondrial antiviral signaling protein (MAVS)-deficient mice. CONCLUSION: The animal model described here reproduces important characteristics of human HDV infection and provides a valuable tool for characterizing the viral infection and for developing new treatments. Furthermore, MAVS was identified as a main player in HDV detection and adaptive immunity was found to be involved in the amplification of the innate immune response. Lay summary: Co-infection with hepatitis B and D virus (HBV and HDV, respectively) often causes a more severe disease condition than HBV alone. Gaining more insight into HDV and developing new treatments is hampered by limited availability of adequate immune competent small animal models and new ones are needed. Here, a mouse model of HDV infection is described, which mimics several important characteristics of the human disease, such as the initiation and maintenance of replication in murine hepatocytes, genome editing and, in the presence of HBV, generation of infectious particles. Lastly, the involvement of an adaptive immunity and the intracellular signaling molecule MAVS in mounting a strong and lasting innate response was shown. Thus, our model serves as a useful tool for the investigation of HDV biology and new treatments.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/imunologia , Hepatite D/imunologia , Interferon beta/biossíntese , Imunidade Adaptativa , Proteínas Adaptadoras de Transdução de Sinal/deficiência , Proteínas Adaptadoras de Transdução de Sinal/genética , Animais , Linhagem Celular , Coinfecção/imunologia , Coinfecção/patologia , Coinfecção/virologia , Dependovirus/genética , Modelos Animais de Doenças , Genoma Viral , Hepatite B/complicações , Hepatite B/imunologia , Hepatite B/virologia , Antígenos da Hepatite B/metabolismo , Vírus da Hepatite B/genética , Vírus da Hepatite B/imunologia , Hepatite D/complicações , Hepatite D/virologia , Vírus Delta da Hepatite/genética , Vírus Delta da Hepatite/imunologia , Vírus Delta da Hepatite/fisiologia , Antígenos da Hepatite delta/metabolismo , Humanos , Imunidade Inata , Fígado/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Modelos Imunológicos , Transdução de Sinais/imunologia , Replicação Viral
7.
J Clin Microbiol ; 55(2): 504-509, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27927921

RESUMO

The unequivocal identification of hepatitis C virus (HCV) subtypes 1a/1b and genotypes 2 to 6 is required for optimizing the effectiveness of interferon-free, direct-acting antiviral therapies. We compared the performance of a new real-time HCV genotyping assay used on the Cobas 4800 system (C4800) with that of high-resolution HCV subtyping (HRCS). In total, 502 samples were used, including 184 samples from chronic HCV patients (from routine laboratory activity during April 2016), 5 stored samples with double HCV genotype infections for testing the limitations of the method, and 313 samples from a screening protocol implemented in our hospital (from May to August 2016) based on the new method to further determine its genotyping accuracy. A total of 282 samples, including 171 from April 2016 (the 13 remaining had too low of a viral load for HRCS), 5 selected with double infections, and 106 from screening, were analyzed by both methods, and 220 were analyzed only by the C4800. The C4800 correctly subtyped 125 of 126 1a/1b samples, and the 1 remaining sample was reported as genotype 1. The C4800 correctly genotyped 38 of 45 non-1a/1b samples (classified by HRCS), and it reported the remaining 7 samples as indeterminate. One hundred two of 106 non-1a/1b genotype samples that were identified using the C4800 for screening were confirmed by HRCS. In the 4 remaining samples, 3 were correctly reported as genotype 1 (without defining the subtype) and 1 was reported as indeterminate. None of the samples were misgenotyped. Four of 7 samples with double HCV infections were correctly genotyped by the C4800. Excluding the 5 selected double-infected samples, the C4800 showed 95.7% concordant results for genotyping HCVs 2 to 6 and 1a/1b subtyping, and 99.2% concordance for subtyping 1a/1b single infections in clinical samples. To improve laboratory workflow, we propose using the C4800 as a first-line test for HCV genotyping and 1a/1b classification, followed by transferring non-1a/1b samples to a center where HRCS is available, if further characterization is needed.


Assuntos
Automação Laboratorial/métodos , Técnicas de Genotipagem/métodos , Hepacivirus/classificação , Hepacivirus/genética , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Análise de Sequência de DNA/métodos , Hepatite C Crônica/diagnóstico , Hepatite C Crônica/virologia , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...